Location
PADDOCK HOUSE
STANGHOW ROAD
SKELTON-IN-CLEVELAND
SALTBURN BY THE SEA
TS12 2AB
Proposal
Discharge of condition 3c, d and e (Contaminated land) of planning permission R/2021/1082/FF for change of use and conversion of vacant storage building to holiday let including external alterations; rendering; perimeter fencing 1.5m high and associated landscaping
Application Type
Condition Discharge
Status
Approved
Parish(es)
Lockwood CP
Skelton and Brotton CP
Applicant
Mr and Mrs Barker
Applicant's Address
Paddock House
Stanghow Road
Skelton
TS12 2BD
Agent
STOVELL & MILLWATER
Agent's Address
5 BRENTNALL CENTRE
BRENTNALL STREET
MIDDLESBROUGH
TS1 5AP
Agent's work phone
01642 232397
Agent's email
planning@davidstovellandmillwater.co.uk
Case Officer
Mr K Robinson
Case Officer Telephone
01287 612445
Case Officer Email
kevin.robinson@redcar-cleveland.gov.uk
Consultation Start
-
Weekly List Expiry Date
-
Date Received
03/04/2025
Date Valid
07/04/2025
Expiry
02/06/2025
Consultation Expiry
-
associated_bldreg
-
Decision
CONDITION DISCHARGE GRANTED
Decision Date
22/05/2025
Decision Level
Delegated
| # | Condition Details |
|---|---|
| 1 | Unless otherwise agreed by the Local Planning Authority in writing, development other than that required to be carried out as part of an approved scheme of remediation must not commence until parts (a) to (c) have been complied with. If unexpected contamination is found after development has begun, development must be halted on that part of the site affected by the unexpected contamination to the extent specified by the Local Planning Authority in writing until condition (e) has been complied with in relation to that contamination. (c) Implementation of Approved Remediation Scheme The approved remediation scheme must be carried out in accordance with its terms prior to the commencement of development other than that required to carry out remediation, unless otherwise agreed in writing by the Local Planning Authority. The Local Planning Authority must be given two weeks written notification of commencement of the remediation scheme works. Following completion of measures identified in the approved remediation scheme, a verification report that demonstrates the effectiveness of the remediation carried out must be produced, and is subject to the approval in writing of the Local Planning Authority. (d) Reporting of Unexpected Contamination In the event that contamination is found at any time when carrying out the approved development that was not previously identified it must be reported in writing immediately to the Local Planning Authority. An investigation and risk assessment must be undertaken in accordance with the requirements of part (a) and where remediation is necessary a remediation scheme must be prepared in accordance with the requirements of part (b), which is subject to the approval in writing of the Local Planning Authority. Following completion of measures identified in the approved remediation scheme a verification report must be prepared, which is subject to the approval in writing of the Local Planning Authority. (e) Long Term Monitoring and Maintenance A monitoring and maintenance scheme to include monitoring the long-term effectiveness of the proposed remediation over a period of 10 years, and the provision of reports on the same must be prepared, both of which are subject to the approval in writing of the Local Planning Authority. Following completion of the measures identified in that scheme and when the remediation objectives have been achieved, reports that demonstrate the effectiveness of the monitoring and maintenance carried out must be produced, and submitted to the Local Planning Authority. This must be conducted in accordance with Environment Agency’s Land Contamination Risk Management Guidance REASON : To ensure that risks from land contamination to the future users of the land and neighbouring land are minimised, together with those to controlled waters, property and ecological systems, and to ensure that the development can be carried out safely without unacceptable risks to workers, neighbours and other offsite receptors. REASON FOR PRE-COMMENCEMENT: The information is required prior to any works commencing on site it relates to land contamination details which are often the first works on site and relate to site preparation. |
If you are unable to find the decision notice that relates to this planning application, please email planning_admin@redcar-cleveland.gov.uk and we will provide this document to you.
To view individual documents click on the file name for the required row and the document will open. To download a selection of individual documents, place a tick alongside each of the ones you wish to view and then click on the 'Download selected' button. To open the sub-tables, click the sub-heading for the group.
| Select all | Size | Date uploaded | |
|---|---|---|---|
| Application Form | |||
| Application Form | 291 kb | 03/04/2025 | |
| Consultee Responses | |||
| Consultee response - Environmental Protection (Nuisance) | 237 kb | 08/04/2025 | |
| Consultee response - Environmental Protection (Contaminated Land) | 238 kb | 22/04/2025 | |
| Decision | |||
| Decision Notice | 121 kb | 22/05/2025 | |
| Officer Report | |||
| Compliance Officer Report | 90 kb | 22/05/2025 | |
| Supporting Documentation | |||
| Condition 3 - Phase 4 Validation Statement | 2927 kb | 03/04/2025 | |
| Consultee Name | Date Letter Sent | Consultation Expiry Date |
|---|---|---|
| Councillor A Oliver (SKELTON EAST) | 08/04/2025 | - |
| Councillor J Thompson (SKELTON EAST) | 08/04/2025 | - |
| Councillor S Kay (LOCKWOOD) | 08/04/2025 | - |
| Environmental Protection Team | 08/04/2025 | - |