R/2019/0031/FFM

Planning Application Details - Official Consultation has expired.

Location
FORMER CRODA SITE WILTON INTERNATIONAL REDCAR
Proposal
CONSTRUCTION AND OPERATION OF A PLASTIC CONVERSION FACILITY INCLUDING OFFICE AND WELFARE BUILDINGS, WORKSHOPS, WEIGHBRIDGES AND ASSOCIATED INFRASTRUCTURE
Application Type
Major Application
Status
Approved
Parish(es)
Applicant
TOURIAN RENEWABLES LTD
Applicant's Address
MR GARY TOOMEY SUITE 19 CITY QUADRANT 11 WATERLOO STREET NEWCASTLE UPON TYNE NE1 4DP
Agent
SIRIUS PLANNING
Agent's Address
4245 PARK APPROACH THORPE PARK LEEDS LS15 8GB
Agent's work phone
Agent's email
Case Officer
Mrs H Conti
Case Officer Telephone
01287 612340
Case Officer Email
helen.conti@redcar-cleveland.gov.uk
Consultation Start
17/01/2019
Weekly List Expiry Date
18/01/2019
Date Received
11/01/2019
Date Valid
11/01/2019
Expiry
12/04/2019
Consultation Expiry
22/02/2019
associated_bldreg
-
Decision
GRANT PLANNING PERMISSION
Decision Date
09/04/2019
Decision Level
Delegated

Conditions table
# Condition Details
1 The development shall not be begun later than the expiration of THREE YEARS from the date of this permission. REASON: Required to be imposed pursuant to Section 91 of the Town and Country Planning Act 1990.
2 The development hereby permitted shall be carried out in accordance with the following approved plans: ARM1002/19/01 REV 0 received by the Local Planning Authority on 11th January 2019 ARM1002/19/02 REV 0 received by the Local Planning Authority on 11th January 2019 ARM1002/19/03 REV 0 received by the Local Planning Authority on 11th January 2019 ARM1002/19/04 REV 0 received by the Local Planning Authority on 11th January 2019 ARM1002/19/05 REV 0 received by the Local Planning Authority on 11th January 2019 ARM1002/19/06 REV 0 received by the Local Planning Authority on 11th January 2019 ARM1002/19/07 REV 0 received by the Local Planning Authority on 11th January 2019 ARM1002/19/08 REV 0 received by the Local Planning Authority on 11th January 2019 ARM1002/19/09 REV 0 received by the Local Planning Authority on 11th January 2019 ARM1002/19/10 REV 0 received by the Local Planning Authority on 11th January 2019 REASON: To accord with the terms of the planning application.
3 Unless otherwise agreed by the Local Planning Authority in writing, development other than that required to be carried out as part of an approved scheme of remediation must not commence until parts (a) to (c) have been complied with. If unexpected contamination is found after development has begun, development must be halted on that part of the site affected by the unexpected contamination to the extent specified by the Local Planning Authority in writing until condition (e) has been complied with in relation to that contamination. (a) Site Characterisation An investigation and risk assessment, in addition to any assessment provided with the planning application, must be completed in accordance with a scheme to assess the nature and extent of any contamination on the site, whether or not it originates on the site. The contents of the scheme are subject to the approval in writing of the Local Planning Authority. The investigation and risk assessment must be undertaken by competent persons and a written report of the findings must be produced. The written report is subject to the approval in writing of the Local Planning Authority. The report of the findings must include: (i) a survey of the extent, scale and nature of contamination; (ii) an assessment of the potential risks to: • human health, • property (existing or proposed) including buildings, crops, livestock, pets, woodland and service lines and pipes, • adjoining land, • groundwaters and surface waters, • ecological systems, • archeological sites and ancient monuments; (iii) an appraisal of remedial options, and proposal of the preferred option(s). This must be conducted in accordance with DEFRA and the Environment Agency’s ‘Model Procedures for the Management of Land Contamination, CLR 11’. (b) Submission of Remediation Scheme A detailed remediation scheme to bring the site to a condition suitable for the intended use by removing unacceptable risks to human health, buildings and other property and the natural and historical environment must be prepared, and is subject to the approval in writing of the Local Planning Authority. The scheme must include all works to be undertaken, proposed remediation objectives and remediation criteria, timetable of works and site management procedures. The scheme must ensure that the site will not qualify as contaminated land under Part 2A of the Environmental Protection Act 1990 in relation to the intended use of the land after remediation. (c) Implementation of Approved Remediation Scheme The approved remediation scheme must be carried out in accordance with its terms prior to the commencement of development other than that required to carry out remediation, unless otherwise agreed in writing by the Local Planning Authority. The Local Planning Authority must be given two weeks written notification of commencement of the remediation scheme works. Following completion of measures identified in the approved remediation scheme, a verification report (referred to in PPS23 as a validation report) that demonstrates the effectiveness of the remediation carried out must be produced, and is subject to the approval in writing of the Local Planning Authority. (d) Reporting of Unexpected Contamination In the event that contamination is found at any time when carrying out the approved development that was not previously identified it must be reported in writing immediately to the Local Planning Authority. An investigation and risk assessment must be undertaken in accordance with the requirements of part (a) and where remediation is necessary a remediation scheme must be prepared in accordance with the requirements of part (b), which is subject to the approval in writing of the Local Planning Authority. Following completion of measures identified in the approved remediation scheme a verification report must be prepared, which is subject to the approval in writing of the Local Planning Authority. (e) Long Term Monitoring and Maintenance A monitoring and maintenance scheme to include monitoring the long-term effectiveness of the proposed remediation over a period of 10 years, and the provision of reports on the same must be prepared, both of which are subject to the approval in writing of the Local Planning Authority. Following completion of the measures identified in that scheme and when the remediation objectives have been achieved, reports that demonstrate the effectiveness of the monitoring and maintenance carried out must be produced, and submitted to the Local Planning Authority. This must be conducted in accordance with DEFRA and the Environment Agency’s ‘Model Procedures for the Management of Land Contamination, CLR 11’ REASON : To ensure that risks from land contamination to the future users of the land and neighbouring land are minimised, together with those to controlled waters, property and ecological systems, and to ensure that the development can be carried out safely without unacceptable risks to workers, neighbours and other offsite receptors. REASON FOR PRE-COMMENCEMENT: The information is required prior to any works commencing on site it relates to land contamination details which are often the first works on site and relate to site preparation.
4 All process plant enclosures shall be designed to have a minimum specification of Rw=40dB. REASON: In the interest of the amenities of the area and to prevent increased background noise levels.
5 Prior to the commencement of the development, or in such extended time as may be agreed in writing with the Local Planning Authority, details shall be submitted and approved of the surface water drainage scheme and the development shall be completed in accordance with the approved scheme. The design of the drainage scheme shall include; (i) Restriction of surface water greenfield run-off rates (QBAR value) with sufficient storage within the system to accommodate a 1 in 30 year storm. (ii)The method used for calculation of the existing greenfield run-off rate shall be the ICP SUDS method. The design shall also ensure that storm water resulting from a 1 in 100 year event, plus climate change surcharging the system, can be stored on site with minimal risk to persons or property and without overflowing into drains, local highways or watercourses. (iii) Full Micro Drainage design files (mdx files) including a catchment plan (iv) The flow path of flood waters for the site as a result on a 1 in 100 year event plus climate change REASON: To ensure the development is supported by a suitably designed surface water disposal infrastructure scheme and to minimise the risk flooding in the locality. REASON FOR PRE-COMMENCEMENT: The information is required prior to any works commencing on site it relates to drainage details which are often the first works on site and relate to site preparation.
6 Statement of Co-operative Working: The Local Planning Authority considers that the application as originally submitted is a satisfactory scheme and therefore no negotiations have been necessary.

If you are unable to find the decision notice that relates to this planning application, please email planning_admin@redcar-cleveland.gov.uk and we will provide this document to you.

To view individual documents click on the file name for the required row and the document will open. To download a selection of individual documents, place a tick alongside each of the ones you wish to view and then click on the 'Download selected' button. To open the sub-tables, click the sub-heading for the group.

Select all Size Date uploaded
Application Form
Application Form 377 kb 11/01/2019
Consultee Responses
Consultee response - Health & Safety Executive PADHI+ 393 kb 17/01/2019
Consultee response - Natural Heritage Manager 70 kb 21/01/2019
Consultee response - Cleveland Police 38 kb 21/01/2019
Consultee response - Northumbrian Water 112 kb 01/02/2019
Consultee response - Environmental Protection (Nuisance) 12 kb 04/02/2019
Consultee response - Environmental Protection (Contaminated Land) 9 kb 04/02/2019
Consultee response - Natural England 243 kb 05/02/2019
Consultee response - Highways England 160 kb 05/02/2019
Consultee response - Environment Agency 206 kb 08/02/2019
Consultee response - Development Engineers 38 kb 11/02/2019
Consultee response - Engineers (Drainage LLFA) 71 kb 13/02/2019
Decision
Decision Notice 149 kb 09/04/2019
Location Plan
Location Plan 837 kb 11/01/2019
Plans
Site Plan 247 kb 11/01/2019
Site Layout Plan 594 kb 11/01/2019
Elevations of Site 592 kb 11/01/2019
Roof Plan 639 kb 11/01/2019
Floor Layout Plans of Office / Welfare Building 404 kb 11/01/2019
Drainage Plan 609 kb 11/01/2019
Swept Path Plan 1114 kb 11/01/2019
Elevation of Fencing 252 kb 11/01/2019
Flow Schematic Plan of CAT - HTR Process 332 kb 11/01/2019
Supporting Documentation
Landscape & Visual Impact Assessment 17387 kb 10/01/2019
Air Quality Assessment 2383 kb 11/01/2019
Biodiversity Survey and Report 1425 kb 11/01/2019
Design and Access Statement 447 kb 11/01/2019
Flood Risk Assessment 1378 kb 11/01/2019
GeoEnvironmental Report Part 1 3501 kb 11/01/2019
GeoEnvironmental Report Part 2 3399 kb 11/01/2019
Noise Impact Assessment 810 kb 11/01/2019
Planning Statement 662 kb 11/01/2019
Statement of Community Involvement 3405 kb 11/01/2019
Transport Assessment 459 kb 11/01/2019
Consultee Name Date Letter Sent Consultation Expiry Date
Cleveland Police ALO - Steve Cranston 17/01/2019 -
Engineering Team (Highways) 17/01/2019 -
Engineers (Local Lead Flood Authority) 17/01/2019 -
Environment Agency 17/01/2019 -
Environmental Protection Team 17/01/2019 -
Executive Management Team 17/01/2019 -
Health & Safety-Food (Food Team) 17/01/2019 -
Health and Safety Executive 17/01/2019 -
National Highways 17/01/2019 -
Natural England 17/01/2019 -
Natural Heritage Manager 17/01/2019 -
Northumbrian Water Ltd 17/01/2019 -
Place Investment Team 17/01/2019 -
Strategic Planning Team (Policy) 17/01/2019 -
Address Date Sent Date Reconsulted Expiry Date
27 DELTA PLACE BATH ROAD CHELTENHAM GL53 7HG 17/01/2019 - 07/02/2019
WILTON INTERNATIONAL REDCAR TS90 8WS 17/01/2019 - 07/02/2019
Site or Press Description Display Date Expiry Date
B ARTICLE 15 01/02/2019 22/02/2019