R/2017/0730/FFM

Planning Application Details - Official Consultation has expired.

Location
LAND AT WILTON INTERNATIONAL
Proposal
CONSTRUCTION AND OPERATION OF A PLASTIC CONVERSION FACILITY INCLUDING OFFICE AND WELFARE BUILDINGS, WORKSHOPS, WEIGHBRIDGES, ASSOCIATED INFRASTRUCTURE AND TEMPORARY OFF-SITE CAR PARK AND SET DOWN AREA
Application Type
Major Application
Status
Approved
Parish(es)
Applicant
TOURIAN RENEWABLES LTD
Applicant's Address
SUITE 34 CITY QUADRANT 11 WATERLOO STREET NEWCASTLE UPON TYNE NE1 4DP
Agent
SIRIUS PLANNING
Agent's Address
4245 PARK APPROACH THORPE PARK LEEDS LS15 8GB
Agent's work phone
Agent's email
Case Officer
Mrs C Griffiths
Case Officer Telephone
01287 612629
Case Officer Email
claire.griffiths@redcar-cleveland.gov.uk
Consultation Start
19/10/2017
Weekly List Expiry Date
27/10/2017
Date Received
13/10/2017
Date Valid
13/10/2017
Expiry
12/01/2018
Consultation Expiry
17/11/2017
associated_bldreg
R/2017/0615/SB
Decision
GRANT PLANNING PERMISSION
Decision Date
12/01/2018
Decision Level
Delegated

Conditions table
# Condition Details
1 The development shall not be begun later than the expiration of THREE YEARS from the date of this permission. REASON: Required to be imposed pursuant to Section 91 of the Town and Country Planning Act 1990.
2 The development hereby permitted shall be carried out in accordance with the following approved plans: ARM1001/19/03 received by the Local Planning Authority on 13/10/2017 ARM1001/19/04 received by the Local Planning Authority on 13/10/2017 ARM1001/19/06 received by the Local Planning Authority on 13/10/2017 ARM1001/19/05 received by the Local Planning Authority on 13/10/2017 ARM1001/19/07 received by the Local Planning Authority on 13/10/2017 ARM1001/19/08 received by the Local Planning Authority on 13/10/2017 ARM1001/19/10 received by the Local Planning Authority on 13/10/2017 ARM1001/19/09 received by the Local Planning Authority on 13/10/2017 REASON: To accord with the terms of the planning application.
3 Unless otherwise agreed by the Local Planning Authority in writing, development other than that required to be carried out as part of an approved scheme of remediation must not commence until parts (a) to (c) have been complied with. If unexpected contamination is found after development has begun, development must be halted on that part of the site affected by the unexpected contamination to the extent specified by the Local Planning Authority in writing until condition (e) has been complied with in relation to that contamination. (a) Site Characterisation An investigation and risk assessment, in addition to any assessment provided with the planning application, must be completed in accordance with a scheme to assess the nature and extent of any contamination on the site, whether or not it originates on the site. The contents of the scheme are subject to the approval in writing of the Local Planning Authority. The investigation and risk assessment must be undertaken by competent persons and a written report of the findings must be produced. The written report is subject to the approval in writing of the Local Planning Authority. The report of the findings must include: (i) a survey of the extent, scale and nature of contamination; (ii) an assessment of the potential risks to: • human health, • property (existing or proposed) including buildings, crops, livestock, pets, woodland and service lines and pipes, • adjoining land, • groundwaters and surface waters, • ecological systems, • archeological sites and ancient monuments; (iii) an appraisal of remedial options, and proposal of the preferred option(s). This must be conducted in accordance with DEFRA and the Environment Agency’s ‘Model Procedures for the Management of Land Contamination, CLR 11’. (b) Submission of Remediation Scheme A detailed remediation scheme to bring the site to a condition suitable for the intended use by removing unacceptable risks to human health, buildings and other property and the natural and historical environment must be prepared, and is subject to the approval in writing of the Local Planning Authority. The scheme must include all works to be undertaken, proposed remediation objectives and remediation criteria, timetable of works and site management procedures. The scheme must ensure that the site will not qualify as contaminated land under Part 2A of the Environmental Protection Act 1990 in relation to the intended use of the land after remediation. (c) Implementation of Approved Remediation Scheme The approved remediation scheme must be carried out in accordance with its terms prior to the commencement of development other than that required to carry out remediation, unless otherwise agreed in writing by the Local Planning Authority. The Local Planning Authority must be given two weeks written notification of commencement of the remediation scheme works. Following completion of measures identified in the approved remediation scheme, a verification report (referred to in PPS23 as a validation report) that demonstrates the effectiveness of the remediation carried out must be produced, and is subject to the approval in writing of the Local Planning Authority. (d) Reporting of Unexpected Contamination In the event that contamination is found at any time when carrying out the approved development that was not previously identified it must be reported in writing immediately to the Local Planning Authority. An investigation and risk assessment must be undertaken in accordance with the requirements of part (a) and where remediation is necessary a remediation scheme must be prepared in accordance with the requirements of part (b), which is subject to the approval in writing of the Local Planning Authority. Following completion of measures identified in the approved remediation scheme a verification report must be prepared, which is subject to the approval in writing of the Local Planning Authority. (e) Long Term Monitoring and Maintenance A monitoring and maintenance scheme to include monitoring the long-term effectiveness of the proposed remediation over a period of 10 years, and the provision of reports on the same must be prepared, both of which are subject to the approval in writing of the Local Planning Authority. Following completion of the measures identified in that scheme and when the remediation objectives have been achieved, reports that demonstrate the effectiveness of the monitoring and maintenance carried out must be produced, and submitted to the Local Planning Authority. This must be conducted in accordance with DEFRA and the Environment Agency’s ‘Model Procedures for the Management of Land Contamination, CLR 11’ REASON : To ensure that risks from land contamination to the future users of the land and neighbouring land are minimised, together with those to controlled waters, property and ecological systems, and to ensure that the development can be carried out safely without unacceptable risks to workers, neighbours and other offsite receptors.
4 All process plant enclosures shall be designed to have a minimum specification of Rw=40dB. REASON: In the interest of the amenities of the area and to prevent increased background noise levels.
5 Prior to the commencement of the development, or in such extended time as may be agreed in writing with the Local Planning Authority, details shall be submitted and approved of the surface water drainage scheme and the development shall be completed in accordance with the approved scheme. The design of the drainage scheme shall include; (i) Restriction of surface water greenfield run-off rates (QBAR value) with sufficient storage within the system to accommodate a 1 in 30 year storm. (ii)The method used for calculation of the existing greenfield run-off rate shall be the ICP SUDS method. The design shall also ensure that storm water resulting from a 1 in 100 year event, plus climate change surcharging the system, can be stored on site with minimal risk to persons or property and without overflowing into drains, local highways or watercourses. (iii) Full Micro Drainage design files (mdx files) including a catchment plan (iv) The flow path of flood waters for the site as a result on a 1 in 100 year event plus climate change REASON: To ensure the development is supported by a suitably designed surface water disposal infrastructure scheme and to minimise the risk flooding in the locality.
6 Statement of Co-operative Working: The Local Planning Authority considers that the application as originally submitted is a satisfactory scheme and therefore no negotiations have been necessary.

If you are unable to find the decision notice that relates to this planning application, please email planning_admin@redcar-cleveland.gov.uk and we will provide this document to you.

To view individual documents click on the file name for the required row and the document will open. To download a selection of individual documents, place a tick alongside each of the ones you wish to view and then click on the 'Download selected' button. To open the sub-tables, click the sub-heading for the group.

Select all Size Date uploaded
Application Form
Application Form 342 kb 13/10/2017
Consultee Responses
Consultee response - Health & Safety Executive PADHI+ 406 kb 19/10/2017
Consultee response - Natural heritage manager 40 kb 19/10/2017
Consultee response - Development Engineers 12 kb 27/10/2017
Consultee response - Crime Prevention 50 kb 01/11/2017
Consultee response - Environment Agency 98 kb 02/11/2017
Consultee response - Environmental Protection (Contaminated Land) 15 kb 06/11/2017
Consultee response - Environmental Protection (Nuisance) 30 kb 07/11/2017
Consultee response - Engineers (Drainage LLFA) 100 kb 07/11/2017
Consultee response - Highways England 206 kb 08/11/2017
Consultee response - Strategic Planning 19 kb 09/11/2017
Consultee response - Northumbrian Water 41 kb 09/11/2017
Decision
Decision Notice 155 kb 12/01/2018
Location Plan
Location Plan 544 kb 13/10/2017
Plans
Site Plans 134 kb 13/10/2017
Site Layout Plan 451 kb 13/10/2017
Elevations of Site 348 kb 13/10/2017
Roof Plans 468 kb 13/10/2017
Floor Layout Plans of Office and Welfare Buildings 348 kb 13/10/2017
Scheme of Drainage 786 kb 13/10/2017
Traffic Management Plan 517 kb 13/10/2017
Security Fencing Elevation 120 kb 13/10/2017
Schematic Flow Layout 202 kb 13/10/2017
Supporting Documentation
Geo-Environmental Preliminary Appraisal 16065 kb 13/10/2017
Air Quality Assessment 2366 kb 13/10/2017
Biodiversity Preliminary Survey Report 882 kb 13/10/2017
Design and Access Statement 401 kb 13/10/2017
Landscape and Visual Appraisal 1711 kb 13/10/2017
Visual Appraisal Study Area and Receptor Plan 3600 kb 13/10/2017
Noise Impact Assessment 804 kb 13/10/2017
Planning Statement 856 kb 13/10/2017
Images 1757 kb 13/10/2017
Statement of Community Involvement 1203 kb 13/10/2017
Transport Statement 204 kb 13/10/2017
EIA Screening Opinion Letter 527 kb 13/10/2017
Flood Risk Assessment 4378 kb 13/10/2017
Consultee Name Date Letter Sent Consultation Expiry Date
Cleveland Police ALO - Steve Cranston 19/10/2017 -
Councillor A D Brown (DORMANSTOWN) 19/10/2017 -
Councillor C Cawley (DORMANSTOWN) 19/10/2017 -
Councillor R Goddard (DORMANSTOWN) 19/10/2017 -
Engineering Team (Highways) 19/10/2017 -
Engineers (Local Lead Flood Authority) 19/10/2017 -
Engineers (Local Lead Flood Authority) 19/10/2017 -
Environment Agency 19/10/2017 -
Environmental Protection Team 19/10/2017 -
Executive Management Team 19/10/2017 -
Health & Safety-Food 19/10/2017 -
Health and Safety Executive (HSC) 19/10/2017 -
National Highways 19/10/2017 -
Natural Heritage Manager 19/10/2017 -
Northumbrian Water Ltd 19/10/2017 -
Place Investment Team 19/10/2017 -
Strategic Planning Team (Policy) 19/10/2017 -
Address Date Sent Date Reconsulted Expiry Date
WILTON INTERNATIONAL REDCAR TS90 8WS 19/10/2017 - 09/11/2017
Site or Press Description Display Date Expiry Date
B ARTICLE 15 27/10/2017 17/11/2017