R/2013/0373/FFM

Planning Application Details - Official Consultation has expired.

Location
LAND AT TILBURY ROAD SOUTH BANK TS6 6AW
Proposal
STEEL PORTAL BUILDING FOR USE AS AN ANAEROBIC DIGESTION PLANT; SINGLE STOREY DETACHED OFFICE BUILDING; 6 STORAGE TANKS; ELECTRICITY SUB-STATION; CAR PARKING; HARDSTANDINGS AND ASSOCIATED LANDSCAPING (AMENDED SCHEME)
Application Type
Major Application
Status
Approved
Parish(es)
Applicant
WARD RECYCLING LTD.
Applicant's Address
PUDDLERS ROAD SOUTH TEES INDUSTRIAL PARK SOUTH BANK MIDDLESBROUGH TS6 6TX
Agent
SIMON HALL ARCHITECTURAL DESIGN LTD.
Agent's Address
11 THE LAURELS NORTHALLERTON NORTH YORKSHIRE DL6 1SA
Agent's work phone
Agent's email
Case Officer
Mrs T Forster-Miller
Case Officer Telephone
01287 612474
Case Officer Email
tara.forster@redcar-cleveland.gov.uk
Consultation Start
09/07/2013
Weekly List Expiry Date
19/07/2013
Date Received
22/05/2013
Date Valid
08/07/2013
Expiry
07/10/2013
Consultation Expiry
21/08/2013
associated_bldreg
R/2014/0027/SB
Decision
GRANT PLANNING PERMISSION
Decision Date
20/09/2013
Decision Level
Delegated

Conditions table
# Condition Details
1 The development shall not be begun later than the expiration of THREE YEARS from the date of this permission. REASON: Required to be imposed pursuant to Section 91 of the Town and Country Planning Act 1990.
2 The development hereby permitted shall be carried out in accordance with the following approved plans: Proposed Layout Plan, Job No.SCH443 DWG No.2. REVISION A Proposed Site Plan, Job No. SCH443 DWG No.3. REVISION A Proposed Floor and Roof Plan, Job No. SCH443 DWG 4. No.3. REVISION A Proposed Elevations, Job No. SCH443 DWG 5. No.3. REVISION A Proposed Scene Elevations. Sub-Station Floor Plan and Elevations, Job No. SCH443 DWG 6. No.3. REVISION A Proposed Floor Plan and Elevations. Office Block, Job No. SCH443 DWG. No.7. REVISION A received by the Local Planning Authority on 22 May 2013, and Proposed Typical Elevations - Storage Tanks. Job No. SCH443 DWG. No.8. REVISION A received by the Local Planning Authority on 8 July 2013. REASON: To accord with the terms of the planning application.
3 The use of the site and associated development shall be used for the purposes of an Anaerobic Digestion Plant only and for no other purpose, including any other purpose within Class B1, B2 or B8 of the Town and Country Planning (Use Classes) Order 1987, without the prior written approval of the Local Planning Authority to whom an application must be made. REASON: The parking requirements have been assessed on the use of the site as an Anaerobic Digestion plant, the Local Planning Authority considers it appropriate to limit the use of the site to that described in the planning application to allow it to review parking provision and impact on the local highway network for uses in other employment classes which may result in increased levels of employment and a consequent increased need for parking and servicing on the application site.
4 Prior to the commencement of the development hereby approved details shall be submitted and approved, in writing, of a traffic management plan for the construction phase of the works and the construction of the development completed in accordance with that plan REASON: In the interests of highways safety.
5 The principal access to the site from the adjoining public highway shall achieve minimum sight lines of 2.4m x 43m and be maintained at this standard. In the area enclosed by this visibility splay no physical development greater than 600mm shall take place and any vegetation within this area shall be maintained at or below this height. REASON: In order to maintain adequate visibility splays at the entrance of the site in accordance with adopted standards, in the interests of highway safety.
6 The car parking spaces and HGV turning area shown on the Proposed Layout Plan (Job No.SCH3443, DWG No.2 REVISION A) hereby approved, shall be constructed and completed in accordance with the approved plans, prior to the development first being used and maintained in the approved manner. REASON: In the interests of highways safety and neighbour amenity
7 Prior to the commencement of development, details shall be submitted to and agreed in writing by the Local Planning Authority, of proposals to provide contractors car parking and material storage within the site. The details approved shall be retained for use until completion of the development unless first agreed in writing with the Local Planning Authority. REASON: In the interest of highway safety.
8 Development shall not commence until a detailed scheme for the disposal of surface and foul water from the development hereby approved has been submitted to and approved in writing by the Local Planning Authority in consultation with Northumbrian Water. Thereafter the development shall take place in accordance with the approved details. REASON: To prevent the increased risk of flooding from any sources in accordance with the NPPF.
9 All vehicular areas are to be bound, surfaced and drained, the fall of the new hardstanding and access roads shall not discharge water onto the adopted highway or the railway, but shall drain within curtilage into the approved surface water disposal system. REASON: In the interests of highway safety
10 Unless otherwise agreed by the Local Planning Authority in writing, development other than that required to be carried out as part of an approved scheme of remediation must not commence until parts (a) to (c) have been complied with. If unexpected contamination is found after development has begun, development must be halted on that part of the site affected by the unexpected contamination to the extent specified by the Local Planning Authority in writing until condition (e) has been complied with in relation to that contamination. (a) Site Characterisation An investigation and risk assessment, in addition to any assessment provided with the planning application, must be completed in accordance with a scheme to assess the nature and extent of any contamination on the site, whether or not it originates on the site. The contents of the scheme are subject to the approval in writing of the Local Planning Authority. The investigation and risk assessment must be undertaken by competent persons and a written report of the findings must be produced. The written report is subject to the approval in writing of the Local Planning Authority. The report of the findings must include: (i) a survey of the extent, scale and nature of contamination; (ii) an assessment of the potential risks to: • human health, • property (existing or proposed) including buildings, crops, livestock, pets, woodland and service lines and pipes, • adjoining land, • groundwaters and surface waters, • ecological systems, • archeological sites and ancient monuments; (iii) an appraisal of remedial options, and proposal of the preferred option(s). This must be conducted in accordance with DEFRA and the Environment Agency’s ‘Model Procedures for the Management of Land Contamination, CLR 11’. (b) Submission of Remediation Scheme A detailed remediation scheme to bring the site to a condition suitable for the intended use by removing unacceptable risks to human health, buildings and other property and the natural and historical environment must be prepared, and is subject to the approval in writing of the Local Planning Authority. The scheme must include all works to be undertaken, proposed remediation objectives and remediation criteria, timetable of works and site management procedures. The scheme must ensure that the site will not qualify as contaminated land under Part 2A of the Environmental Protection Act 1990 in relation to the intended use of the land after remediation. (c) Implementation of Approved Remediation Scheme The approved remediation scheme must be carried out in accordance with its terms prior to the commencement of development other than that required to carry out remediation, unless otherwise agreed in writing by the Local Planning Authority. The Local Planning Authority must be given two weeks written notification of commencement of the remediation scheme works. Following completion of measures identified in the approved remediation scheme, a verification report (referred to in PPS23 as a validation report) that demonstrates the effectiveness of the remediation carried out must be produced, and is subject to the approval in writing of the Local Planning Authority. (d) Reporting of Unexpected Contamination In the event that contamination is found at any time when carrying out the approved development that was not previously identified it must be reported in writing immediately to the Local Planning Authority. An investigation and risk assessment must be undertaken in accordance with the requirements of part (a) and where remediation is necessary a remediation scheme must be prepared in accordance with the requirements of part (b), which is subject to the approval in writing of the Local Planning Authority. Following completion of measures identified in the approved remediation scheme a verification report must be prepared, which is subject to the approval in writing of the Local Planning Authority. (e) Long Term Monitoring and Maintenance A monitoring and maintenance scheme to include monitoring the long-term effectiveness of the proposed remediation over a period of 10 years, and the provision of reports on the same must be prepared, both of which are subject to the approval in writing of the Local Planning Authority. Following completion of the measures identified in that scheme and when the remediation objectives have been achieved, reports that demonstrate the effectiveness of the monitoring and maintenance carried out must be produced, and submitted to the Local Planning Authority. This must be conducted in accordance with DEFRA and the Environment Agency’s ‘Model Procedures for the Management of Land Contamination, CLR 11’ REASON : To ensure that risks from land contamination to the future users of the land and neighbouring land are minimised, together with those to controlled waters, property and ecological systems, and to ensure that the development can be carried out safely without unacceptable risks to workers, neighbours and other offsite receptors.
11 A landscaping scheme shall be submitted to, and approved in writing by, the Local Planning Authority prior to the commencement of development. The details shall include size, type and species of plant and indicate the proposed layout and surfacing of all open areas. A programme of work shall also be submitted and implemented in accordance with the approved details. REASON: To reserve the rights of the Local Planning Authority with regard to these matters.
12 All planting, seeding or turfing comprised in the approved details of landscaping shall be carried out in the first planting and seeding season following the occupation of the buildings or the completion of the development, whichever is sooner, and any trees or plants which within a period of ten years from the completion of the development die, are removed, or become seriously damaged or diseased shall be replaced in the next planting season with others of similar size and species unless the Local Planning Authority gives written consent to any variation. REASON: To ensure the satisfactory implementation of the approved scheme in the interests of the visual amenities of the locality.
13 The Local Planning Authority consider that the application as originally submitted is a satisfactory scheme and therefore no negotiations have been necessary.
14 An Environmental Permit is required from the Environment Agency before the proposed development becomes operational. The applicant is advised to contact the Environment Agency in respect of this matter
15 The applicant is advised to contact Niki Mather (Tel 0191 419 6603 Email niki.mather@nwl.co.uk) to discuss the redesign of the proposal to ensure the protection of and access to Northumbrian Water’s sewerage apparatus both during construction and after the development has been completed. The applicant is also advised to contact Peter Heppell (Tel 0191 419 6619 Email peter.heppell@nwl.co.uk) to discuss the location, protection of and access to a water main that crosses the site.

If you are unable to find the decision notice that relates to this planning application, please email planning_admin@redcar-cleveland.gov.uk and we will provide this document to you.

To view individual documents click on the file name for the required row and the document will open. To download a selection of individual documents, place a tick alongside each of the ones you wish to view and then click on the 'Download selected' button. To open the sub-tables, click the sub-heading for the group.

Select all Size Date uploaded
Application Form
Application Form 132 kb 22/05/2013
Decision
Decision Notice 54 kb 20/09/2013
Location Plan
Location Plan 41 kb 22/05/2013
Plans
Existing Site Plan 293 kb 22/05/2013
Proposed Layout Plan 441 kb 22/05/2013
Floor and Roof Plans of Steel Portal Building 384 kb 22/05/2013
Elevations of Steel Portal Building 3173 kb 22/05/2013
Plans and Elevations of Office Building 499 kb 22/05/2013
Elevations of Steel Portal and Electricity Sub-Station Buildings 2030 kb 22/05/2013
Elevations of Storage Tanks 378 kb 08/07/2013
Proposed Site Plan 423 kb 08/07/2013
Supporting Documentation
Design and Access Statement 35 kb 22/05/2013
Air Quality Assessment 32 kb 22/05/2013
Noise Impact Assessment 1029 kb 22/05/2013
Flood Risk Assessment 39 kb 22/05/2013
Screening Appraisal 51 kb 22/05/2013
Application Documents
Screening Opinion Response Reg 7 99 kb 09/08/2013
Consultee Name Date Letter Sent Consultation Expiry Date
Aboricultural Officer 09/07/2013 -
Commercial Investment (Regen) 09/07/2013 -
Councillor I Jeffrey (SOUTH BANK) 09/07/2013 -
Councillor P Spencer (HUTTON) 09/07/2013 -
Councillor S Jeffrey (SOUTH BANK) 09/07/2013 -
Councillor S Szintai 09/07/2013 -
Engineering Team (Highways) 09/07/2013 -
Environment Agency 09/07/2013 -
Environmental Protection Team 09/07/2013 -
Health & Safety-Food 09/07/2013 -
Health & Safety-Food (Food Team) 09/07/2013 -
National Highways 09/07/2013 -
Network Rail 09/07/2013 -
Northern Powergrid 09/07/2013 -
Northern Powergrid 17/07/2013 -
Northumbrian Water Ltd 09/07/2013 -
Regeneration (South Tees) 09/07/2013 -
Strategic Planning Team (Policy) 09/07/2013 -
Address Date Sent Date Reconsulted Expiry Date
READY MIXED CONCRETE LTD SMITH'S DOCK ROAD SOUTH BANK MIDDLESBROUGH TS6 6AL 09/07/2013 - 30/07/2013
1 IMPERIAL AVENUE SOUTH BANK MIDDLESBROUGH TS6 6BA 09/07/2013 - 30/07/2013
BAKETIME LIMITED UNIT 1 SOUTH TEES IMPERIAL FOOD PARK IMPERIAL AVENUE SOUTH BANK MIDDLESBROUGH TS6 6BA 09/07/2013 - 30/07/2013
Site or Press Description Display Date Expiry Date
B ARTICLE 15 12/07/2013 02/08/2013
S ARTICLE 15 31/07/2013 21/08/2013