R/2013/0369/FFM

Planning Application Details - Official Consultation has expired.

Location
LAND AT WILTON INTERNATIONAL TRUNK ROAD REDCAR
Proposal
PROPOSED ANAEROBIC DIGESTION AND COMBINED HEAT & POWER PLANT
Application Type
Major Application
Status
Approved
Parish(es)
Applicant
EARTHLY ENERGY GROUP
Applicant's Address
A331 - A339 THE WILTON CENTRE REDCAR TS10 4RF
Agent
ENGLAND & LYLE LTD
Agent's Address
GATEWAY HOUSE 55 CONISCLIFFE ROAD DARLINGTON COUNTY DURHAM DL3 7EH
Agent's work phone
Agent's email
Case Officer
Mr D Pedlow
Case Officer Telephone
01287 612546
Case Officer Email
David.Pedlow@redcar-cleveland.gov.uk
Consultation Start
30/05/2013
Weekly List Expiry Date
06/06/2013
Date Received
21/05/2013
Date Valid
23/05/2013
Expiry
22/08/2013
Consultation Expiry
02/07/2013
associated_bldreg
R/2014/0036/SB
Decision
GRANT PLANNING PERMISSION
Decision Date
24/07/2013
Decision Level
Delegated

Conditions table
# Condition Details
1 The development shall not be begun later than the expiration of THREE YEARS from the date of this permission. REASON: Required to be imposed pursuant to Section 91 of the Town and Country Planning Act 1990.
2 The development hereby permitted shall be carried out in accordance with the following approved plans: Drawing Number 13-1100.01 Rev A5 received by the Local Planning Authority on 23/05/13 Drawing Number 13-1100.02 Rev A3 received by the Local Planning Authority on 23/05/13 Drawing Number 13-1100.03 Rev A3 received by the Local Planning Authority on 23/05/13 Drawing Number 13-1100.05 Rev A1 received by the Local Planning Authority on 21/05/13 Drawing Number 13-1100.06 Rev A2 received by the Local Planning Authority on 23/05/13 Drawing Number 13-1100.07 Rev A2 received by the Local Planning Authority on 23/05/13 Drawing Number 13-1100.08 Rev A2 received by the Local Planning Authority on 23/05/13 Drawing Number 13-1100.09 Rev A2 received by the Local Planning Authority on 23/05/13 Drawing Number 13-1100.10 Rev A2 received by the Local Planning Authority on 23/05/13 Drawing Number 13-1100.11 Rev A2 received by the Local Planning Authority on 23/05/13 Drawing Number 13-1100.12 Rev A1 received by the Local Planning Authority on 23/05/13 Drawing Number 13-1100.13 Rev A1 received by the Local Planning Authority on 23/05/13 Drawing Number 13-1100.15 Rev A1 received by the Local Planning Authority on 23/05/13 Drawing Number 13-1100.16 Rev A1 received by the Local Planning Authority on 23/05/13 Drawing Number 13-1100.17 Rev A1 received by the Local Planning Authority on 23/05/13 Drawing Number 13-1100.18 Rev A1 received by the Local Planning Authority on 23/05/13 REASON: To accord with the terms of the planning application.
3 Prior to the commencement of development a scheme demonstrating that noise emissions will be adequately controlled shall be submitted to and approved in writing by the local planning Authority. The scheme shall include sound power level information for all plant and equipment used and the sound attenuation properties of buildings and any noise abatement equipment used. The scheme approved shall be implemented prior to the use commencing and thereafter retained at all times. REASON: To ensure the development does not result in adverse impact on neighbour amenity through the generation of noise.
4 Prior to the commencement of development a scheme demonstrating that odour emissions will be adequately controlled shall be submitted to and approved in writing by the local planning Authority. The scheme should consider the use of negative pressure within buildings, storage areas, silos and whether it is necessary to be vented to odour arrestment plant. The scheme should also include a management plan for any spillages on site. The scheme approved shall be implemented prior to the use commencing and thereafter retained at all times. REASON: To ensure the development does not result in adverse impact on neighbour amenity through the generation of odour
5 Details of the external materials to be used in the carrying out of this permission (including samples) shall be submitted to, and approved in writing by the Local Planning Authority, prior to the commencement of development and the development shall not be carried out except in accordance with the approved details. REASON: To ensure the use of satisfactory materials.
6 The development permitted by this planning permission shall only be carried out in accordance with the approved Flood Risk Assessment (FRA) 3886/FRA1 and the following mitigation measures detailed within the FRA: 1. Limiting the surface water run-off generated by the development to greenfield rates so that it will not exceed the run-off from the undeveloped site and not increase the risk of flooding off-site as outlined in section 10.11. This detail is to be agreed in partnership with the local authority as the surface water will discharge into an ordinary watercourse. 2. Provision of compensatory flood storage as outlined in section 10.15 The mitigation measures shall be fully implemented prior to occupation and subsequently in accordance with the timing / phasing arrangements embodied within the scheme, or within any other period as may subsequently be agreed, in writing, by the local planning authority. Reason 1. To prevent flooding by ensuring the satisfactory storage of/disposal of surface water from the site. 2. To prevent flooding elsewhere by ensuring that compensatory storage of flood 3. To reduce the risk of flooding to the proposed development and future occupants
7 Upon the development becoming operational no deliveries shall be made to the site outside the hours of 8:00 until 18:00 hours Monday to Saturday, and at no time on Sunday. REASON: In the interest of neighbour amenity
8 A landscaping scheme shall be submitted to, and approved in writing by, the Local Planning Authority prior to the commencement of development. The details shall include size, type and species of plant and indicate the proposed layout and surfacing of all open areas. A programme of work should also be submitted and implemented in accordance with the approved details. REASON: To reserve the rights of the Local Planning Authority with regard to these matters.
9 All planting, seeding or turfing comprised in the approved details of landscaping shall be carried out in the first planting and seeding season following the occupation of the buildings or the completion of the development, whichever is sooner, and any trees or plants which within a period of ten years from the completion of the development die, are removed, or become seriously damaged or diseased shall be replaced in the next planting season with others of similar size and species unless the Local Planning Authority gives written consent to any variation. REASON: To ensure the satisfactory implementation of the approved scheme in the interests of the visual amenities of the locality.
10 Informative Note: The application site is on/close to land that has been identified as having a history of potential contamination. It is not considered that the development proposed will give rise to 'significant risk' to health or pollution of controlled waters. It is recommended, however, that the attention of the applicant be drawn to the risk of contaminants in, on or under the site.
11 STATEMENT OF COOPERATIVE WORKING: The Local Planning Authority consider that the application as originally submitted is a satisfactory scheme and therefore no negotiations have been necessary.

If you are unable to find the decision notice that relates to this planning application, please email planning_admin@redcar-cleveland.gov.uk and we will provide this document to you.

To view individual documents click on the file name for the required row and the document will open. To download a selection of individual documents, place a tick alongside each of the ones you wish to view and then click on the 'Download selected' button. To open the sub-tables, click the sub-heading for the group.

Select all Size Date uploaded
Application Form
Application Form 129 kb 21/05/2013
Decision
Decision Notice 43 kb 24/07/2013
Location Plan
Aerial Location Plan 1050 kb 21/05/2013
Location Plan 351 kb 23/05/2013
Plans
Indicative Site Layout 3530 kb 21/05/2013
Proposed CHP Facility Elevations 1475 kb 21/05/2013
Proposed Site Plan 874 kb 23/05/2013
Proposed Pre Storage Tank Facility Elevations 2698 kb 23/05/2013
Proposed Site Elevations 1734 kb 23/05/2013
Proposed Primary Fermenter Tanks Plans and Elevations 2440 kb 23/05/2013
Proposed Fermenter Tanks Plans and Elevations 2059 kb 23/05/2013
Proposed External Solid Material Store Plans and Elevations 1580 kb 23/05/2013
Proposed Digestate Storage Plans and Elevations 1905 kb 23/05/2013
Proposed Pre Storage Tank Facility Plan and Section 1299 kb 23/05/2013
Proposed CHP Facility Floor Plan 1353 kb 23/05/2013
Proposed Pre Storage Tank Facility Floor Plan 1850 kb 23/05/2013
Proposed Site Plan 1637 kb 23/05/2013
Proposed Technical Building Plans and Elevations 1448 kb 23/05/2013
Proposed Site Boundary Fence Details 1028 kb 23/05/2013
Proposed Solid Material Charging System 531 kb 23/05/2013
Supporting Documentation
Design and Access Statement 1842 kb 21/05/2013
Noise impact assessment 1560 kb 21/05/2013
Statement of community involvement 1291 kb 21/05/2013
Air Quality Assessment 7110 kb 21/05/2013
Flood Risk Assessment 5227 kb 23/05/2013
Consultee Name Date Letter Sent Consultation Expiry Date
Commercial Investment (Regen) 30/05/2013 -
Engineering Team (Highways) 30/05/2013 -
Environment Agency 30/05/2013 -
Environmental Protection Team 30/05/2013 -
Northumbrian Water Ltd 30/05/2013 -
Regeneration (South Tees) 30/05/2013 -
Strategic Planning Team (Policy) 30/05/2013 -
Address Date Sent Date Reconsulted Expiry Date
HEADQUARTERS WILTON INTERNATIONAL MIDDLESBROUGH TS90 8WS 30/05/2013 - 20/06/2013
Site or Press Description Display Date Expiry Date
B ARTICLE 15 11/06/2013 02/07/2013