R/2002/0882/OO

Planning Application Details - Official Consultation has expired.

Location
FORMER CLAY LANE BLAST FURNACE COMPLEX, NORTH OF MIDDLESBROUGH ROAD EAST, SOUTH BANK
Proposal
OUTLINE APPLICATION FOR INDUSTRIAL DEVELOPMENT INCLUDING SITE CLEARANCE AND RECLAMATION OF LAND WITH PROVISION OF SITE INFRASTRUCTURE
Application Type
Outline
Status
Approved
Parish(es)
Eston
Applicant
ONE NORTH EAST
Applicant's Address
ST GEORGE'S HOUSE KINGSWAY TEAM VALLEY GATESHEAD NE110NA
Agent
HALCROW GROUP LIMITED
Agent's Address
VALLEY HOUSE VALLEY STREET NORTH DARLINGTON DL1 1TJ
Agent's work phone
Agent's email
Case Officer
Mr G Dyball
Case Officer Telephone
Case Officer Email
Grahame_Dyball@redcar-cleveland.gov.uk
Consultation Start
29/10/2002
Weekly List Expiry Date
-
Date Received
17/10/2002
Date Valid
17/10/2002
Expiry
12/12/2002
Consultation Expiry
06/12/2002
associated_bldreg
-
Decision
OUTLINE PERMISSION GRANTED
Decision Date
28/04/2003
Decision Level
Delegated

Conditions table
# Condition Details
1 (1) The development to which the permission relates must be begun not later than: i) The expiration of five years from the date of the grant of outline planning permission, or ii) If later, the expiration of two years from the final approval of the reserved matters or, in the case of approval on different dates, the final approval of the last such matter to be approved. REASON: Required to be imposed pursuant to Section 92 of the Town and Country Planning Act 1990.
2 (2) There shall be no discharge of foul or contaiminated drainage from the site into either groundwater or any surface waers, whether direct or via soakaways. REASON: To prevent pollution of the water environment.
3 (3) Any facilities for the storage of oils, fuels or chemicals shall be sited on impervious bases and surrounded by impervious bund walls. The volume of the bunded compound should be at least equivalent to the capacity of the tank plus 10%. If there is multiple tankage, the compound should be at least equivalent to the capacity of the largest tank, or the combined capacity of interconnected tanks, plus 10 %. All filling points, vents, gauges and sight glasses must be located within the bund. The drainage system of the bund shall be sealed with no discharge to any watercourse, land or underground strata. Associated pipework should be located above ground and protected from accidental damage. All filling points and tank overflow pipe outlets should be detailed to discharge downwards into the bund. REASON: To prevent pollution of the water environment.
4 (4) The application site is on/close to land identified by the council as having a history of potentially harmful contamination. The applicant shall, prior to the commencement of any works involving the disturbance of the site, submit for the approval of the Planning Authority i) details of a suitable site investigation and risk assessment sufficient to identify the nature and degree of any contaminants in, on or under the site and the extent to which they may effect the suitability of the site for its intended use. ii) dependent on the findings of i) above, details of a suitable remediation scheme. The agreed scheme shall be implemented to the satisfaction of the Local Planning Authority prior to the development commencing. REASON: In the interests of public safety.
5 (5) No development shall take place until there has been submitted to, and agreed in writing by the Local Planning Authority, a scheme of landscaping which shall include indications of all existing trees and hedgerows on the land (if any), and details of any to be retained, together with measures for their protection in the course of the development. REASON: To reserve the rights of the Local Planning Authority with regard to these matters
6 (6) All planting, seeding or turfing comprised in the approved details of landscaping shall be carried out in the first planting and seeding season following the occupation of the buildings or the completion of the development, whichever is sooner, and any trees or plants which within a period of five years from the completion of the development die, are removed, or become seriously damaged or diseased shall be replaced in the next planting season with others of similar size and species unless the Local Planning Authority gives written consent to any variation. REASON: To ensure the satisfactory implementation of the approved scheme in the interests of the visual amenities of the locality.
7 NOTE: Redcar and Cleveland Local Plan Policies GEN1, GEN2 and IND4 were relevant to this decision.

If you are unable to find the decision notice that relates to this planning application, please email planning_admin@redcar-cleveland.gov.uk and we will provide this document to you.

To view individual documents click on the file name for the required row and the document will open. To download a selection of individual documents, place a tick alongside each of the ones you wish to view and then click on the 'Download selected' button. To open the sub-tables, click the sub-heading for the group.

Select all Size Date uploaded
Decision
Decision Notice 30 kb 28/03/2003
Consultee Name Date Letter Sent Consultation Expiry Date
- 04/11/2002 -
Housing & Health Services Division 25/10/2002 -
Northumbrian Water Ltd 25/10/2002 -
Technical Services (Regulatory) 25/10/2002 -
Address Date Sent Date Reconsulted Expiry Date
TRAINING CENTRE MIDDLESBROUGH ROAD EAST SOUTH BANK MIDDLESBROUGH TS6 6TZ 29/10/2002 - 19/11/2002
CLEVELAND TRUCK SHOP PUDDLERS ROAD SOUTH BANK MIDDLESBROUGH TS6 6TZ 29/10/2002 - 19/11/2002
Site or Press Description Display Date Expiry Date
B ARTICLE 15 15/11/2002 06/12/2002